Numerical Simulation and Experimental Study on Auxiliary Converter Cooling System of HXD1C Electric Locomotives
Numerical Simulation and Experimental Study on Auxiliary Converter Cooling System of HXD1C Electric Locomotives
Blog Article
This paper determined the size of the heat sink of auxiliary converter of HXD1C locomotive.The required cooling air volume was calculated through experience formula.Three-dimensional calculation model for duct cooling systems numerical simulation had been set up by SHORT HAIR HARD WAX using CFD software FLUENT, which was used to solve the temperature distribution in the cooling system.
Test results compared with the study results show that the required accuracy meets the requirements of engineering application and the heat analysis Cable Covers can be applied to similar systems.